General technical data: |
product brand name | | SIPLUS ECC1000 |
product designation | | CM-100 |
charging current / maximum | A | 16 |
Product description | | Actuation and monitoring of power components in the charging station, used for communication with the electric vehicle in acc. with IEC61851 |
Protection class IP / on the front | | IP20 |
Degree of pollution | | 3, to IEC/EN 61010-1 |
Insulation voltage / with degree of pollution 3 / rated value | V | 230 |
|
Supply voltage: | | |
Type of voltage / of supply voltage | | DC |
Supply voltage | | |
| V | 24 |
| V | 18… 28 |
Consumed current / for rated value of supply voltage | mA | 300 |
|
Communication: | | |
Product function / bus-communication | | No |
Protocol / is supported | | |
- communication to electric vehicle according to IEC 61851
| | Yes |
| | No |
| | No |
|
Display: | | |
Number of LEDs | | 1 |
Type of display | | |
| | green, flashing / continuously illuminated, waiting for EF / charging active |
- as status display of the inputs
| | orange, flashing (1 Hz), device waiting for enable |
| | red, flashing / twinkling, fault |
|
Inputs/ Outputs: |
Number of interfaces / to IEC 61851 | | 1 |
Number of digital inputs | | 2 |
Type of voltage / of the input voltage | | DC |
Input voltage | V | 0… 5 |
Number of digital outputs | | 0 |
|
Auxiliary circuit: | | |
Number of NO contacts / for auxiliary contacts | | 4 |
Operating current / of auxiliary contacts | | |
| A | 0.75 |
| A | 0.75 |
| A | 1 |
|
Klemmen: | | |
Contact assignment | | |
- of the bushing 1 at the PIN 1
| | I+24 V: 24 V DC connection (SELV) |
- of the bushing 1 at the PIN 2
| | M: 24 V DC connection (SELV) |
- of the bushing 2 at the PIN 1
| | FE: Functional ground (part of the vehicle interface, connection to plug in accordance with IEC61851) |
- of the bushing 2 at the PIN 2
| | PX: Proximity (part of the vehicle interface, connection to plug in accordance with IEC61851) |
- of the bushing 2 at the PIN 3
| | CP: Control Pilot (part of the vehicle interface, connection to plug in accordance with IEC61851) |
- of the bushing 3 at the PIN 1
| | AV: Auxilary voltage (readback voltage for device's own digital inputs) |
- of the bushing 3 at the PIN 2
| | EN: Enable (digital input for module enable) |
- of the bushing 3 at the PIN 3
| | HL: Hatch lock (digital input for status of connector lock) |
- of the bushing 4 at the PIN 1
| | P1: "Power" relay contact for switching load contactor |
- of the bushing 4 at the PIN 2
| | P2: "Power" relay contact for switching load contactor |
- of the bushing 4 at the PIN 3
| | V1: Ventilation relay contact for switching fan |
- of the bushing 4 at the PIN 4
| | V2: Ventilation relay contact for switching fan
|
- of the bushing 4 at the PIN 5
| | H1: Hatch relay contact for switching locking |
- of the bushing 4 at the PIN 6
| | H2: Hatch relay contact for switching locking |
- of the bushing 4 at the PIN 7
| | S1: signal relay contact for reporting faults |
- of the bushing 4 at the PIN 8
| | S2: signal relay contact for reporting faults |
|
Ambient conditions: | | |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -25… +70 |
| °C | -25… +60 |
| °C | -25… +70 |
Relative humidity | | |
| % | 0… 95 |
|
Electromagnetic compatibility: | | |
EMC emitted interference / according to IEC 61000-6-3 | | Suitable for operation in residential, public and industrial environments |
EMC immunity to interference / according to IEC 61000-6-2 | | Suitable for operation in industrial and residential environments |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV / 5 kHz DC supply lines, 2 kV / 5 kHz control lines and relay outputs |
Conductor-bound parasitic coupling SURGE / according to IEC 61000-4-5 | | Asymmetrical: DC supply lines 0.5 kV / 12 ohms; DC supply lines 1 kV / 42 ohms; control lines and functional ground 2 kV / 42 ohms; relay outputs 4kV / 12 ohms; evaluation criterion B. symmetrical: DC supply lines 0.5 kV / 2 ohms; DC |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 80 MHz to 1 GHz 10 V/m, 1.4 GHz to 2 GHz 3 V/m, 2 GHz to 2.7 GHz 1 V/m, evaluation criterion A |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge, evaluation criterion B |
Resistance against shock / according to IEC 60068-2-27 | | 15g / 11 ms / 3 shocks per axis |
Shock resistance / during transport / to IEC 60068-2-29 | | 1000 shocks / axis, 25g, 6 ms semi-sinusoidal |
Vibration resistance | | |
- during transport / to IEC 60068-2-6