3TK2810-1KA41 - SIRIUS SAFETY RELAY SAFETY-RELATED SPEED MONITORING, 110 - 240 V AC/DC, 45.0 MM, SCREW CONNECTION, ENABLING CIRCUIT, INSTANTANEOUS: 2NO, ENABLING CIRCUIT, DELAYED: 0, SIGNALING CIRCUIT: 2 ELECTRICAL, AUTOSTART / MANUAL START, BASIC UNIT, MAX. ERR. PL EN13849-1: E, MAX. ERR. SIL TO IEC61508:3, (siemens) - Quad Industry GmbH

Артикул: 3TK2810-1KA41
Наименование: SIRIUS SAFETY RELAY SAFETY-RELATED SPEED MONITORING, 110 - 240 V AC/DC, 45.0 MM, SCREW CONNECTION, ENABLING CIRCUIT, INSTANTANEOUS: 2NO, ENABLING CIRCUIT, DELAYED: 0, SIGNALING CIRCUIT: 2 ELECTRICAL, AUTOSTART / MANUAL START, BASIC UNIT, MAX. ERR. PL EN13849-1: E, MAX. ERR. SIL TO IEC61508:3, (siemens)
Производитель: Siemens


Наименование продукта
SIRIUS SAFETY RELAY SAFETY-RELATED SPEED MONITORING, 110 - 240 V AC/DC, 45.0 MM, SCREW CONNECTION, ENABLING CIRCUIT, INSTANTANEOUS: 2NO, ENABLING CIRCUIT, DELAYED: 0, SIGNALING CIRCUIT: 2 ELECTRICAL, AUTOSTART / MANUAL START, BASIC UNIT, MAX. ERR. PL EN13849-1: E, MAX. ERR. SIL TO IEC61508:3,
Жизненный цикл продукта
3TK2810-1KA41">
3TK2810-1KA41"> Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
3TK2810-1KA41"> 2010-07-29
SIRIUS SAFETY RELAY SAFETY-RELATED SPEED MONITORING, 110 - 240 V AC/DC, 45.0 MM, SCREW CONNECTION, ENABLING CIRCUIT, INSTANTANEOUS: 2NO, ENABLING CIRCUIT, DELAYED: 0, SIGNALING CIRCUIT: 2 ELECTRICAL, AUTOSTART / MANUAL START, BASIC UNIT, MAX. ERR. PL EN13849-1: E, MAX. ERR. SIL TO IEC61508:3,
 
General technical details:
product brand name   SIRIUS
product designation   safety relays
Design of the product   standstill and speed monitoring
protection class IP / of the housing   IP20
Protection class IP / of the terminal   IP20
Protection against electrical shock   finger-safe
Insulation voltage / rated value V 300
Ambient temperature    
  • during storage
°C -20 +70
  • during operating
°C 0 60
Air pressure    
  • according to SN 31205
kPa 90 106
Relative humidity    
  • during operating phase
% 10 95
Installation altitude / at a height over sea level / maximum m 2,000
Resistance against vibration / according to IEC 60068-2-6   10 ... 55 Hz: 0.35 mm
Resistance against shock   8g / 10 ms
Impulse voltage resistance / rated value V 4,000
EMC emitted interference   EN 60947-5-1
Installation environment relating to EMC   This product is suitable for Class A environments only. It can cause undesired radio-frequency interference in residential environments. If this is the case, the user must take appropriate measures.
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  KT
  • according to DIN EN 61346-2
  F
Number of sensor inputs    
  • 2-channel
  3
  • 1-channel or 2-channel
  0
Design of the cascading   none
Type of the safety-related wiring / of the inputs   single-channel or two-channel
Product feature / transverse contact-secure   Yes
safety Integrated Level    
  • according to IEC 61508
  SIL3
  • for time-delayed enabling circuit / according to IEC 61508
  SIL3
SIL claim limit (for a subsystem) / according to EN 62061   3
Performance level (PL)    
  • according to ISO 13849-1
  e
  • for time-delayed enabling circuit / according to ISO 13849-1
  e
Category / according to EN 954-1   4
Category / according to ISO 13849-1   4
Hardware fault tolerance / according to IEC 61508   1
Safety device type / according to IEC 61508-2   type B
Probability of dangerous failure per hour (PFHD) / with high demand rate / according to EN 62061 1/h 0.34E-8
T1 value / for proof test interval or service life / according to IEC 61508 a 20
Number of outputs / as contact-affected switching element    
  • as NC contact / for reporting function / instantaneous switching
  0
  • as NO contact / for reporting function / instantaneous switching
  0
  • as NC contact / for reporting function / delayed switching
  0
  • as NO contact / for reporting function / delayed switching
  0
  • as NC contact / safety-related / instantaneous switching
  0
  • as NO contact / safety-related / instantaneous switching
  1
  • as NC contact / safety-related / delayed switching
  0
  • as NO contact / safety-related/ delayed switching
  1
Number of outputs / as contact-less semiconductor switching element    
  • safety-related
   
  • delayed switching
  0
  • non-delayed
  0
  • for reporting function
   
  • delayed switching
  1
  • non-delayed
  1
Stop category / according to DIN EN 60204-1   0
 
General technical details:
   
Design of the input    
  • cascading-entrance/operation-even switching
  No
  • reducing-entrance
  Yes
  • start-up entrance
  Yes
Design of the electrical connection / jumper socket   Yes
Switching capacity current    
  • of semiconductor outputs
   
  • for signaling function / for DC-13 / at 24 V
A 0.02
  • of NO contacts of relay outputs
   
  • at DC-13
   
  • at 24 V
A 2
  • at 115 V
A 2
  • at AC-15
   
  • at 24 V
A 3
  • at 230 V
A 3
  • of NC contacts of relay outputs
   
  • at AC-15
   
  • at 24 V
A 3
  • at 115 V
A 3
  • at 230 V
A 2