| SIRIUS SAFETY RELAY WITH RELAY RELEASE CIRCUITS (RC), DC 24V, 45.0MM, SCREW TERMINAL, RC INSTANT.: 3S, RC DELAYED: 0S, MK: 2OE, AUTOSTART / MONITORED START, BASIC DEVICE, MAX. ACHIEVABLE SIL: 3, PL: E |
|
General technical details: |
product brand name | | SIRIUS |
product designation | | safety relays |
Design of the product | | for EMERGENCY-STOP units |
protection class IP / of the housing | | IP20 |
Protection class IP / of the terminal | | IP20 |
Protection against electrical shock | | finger-safe |
Insulation voltage / rated value | V | 300 |
Ambient temperature | | |
| °C | -40… +80 |
| °C | -25… +60 |
Air pressure | | |
| kPa | 90… 106 |
Relative humidity | | |
| % | 10… 95 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Resistance against vibration / according to IEC 60068-2-6 | | 5 ... 500 Hz: 0,075 mm |
Resistance against shock | | 8g / 10 ms |
Impulse voltage resistance / rated value | V | 4,000 |
EMC emitted interference | | EN 60947-5-1 |
Installation environment relating to EMC | | This product is suitable for Class A environments only. It can cause undesired radio-frequency interference in residential environments. If this is the case, the user must take appropriate measures. |
Item designation | | |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | KT |
- according to DIN EN 61346-2
| | F |
Number of sensor inputs | | |
| | 1 |
Design of the cascading | | none |
Type of the safety-related wiring / of the inputs | | single-channel and two-channel |
Product feature / transverse contact-secure | | Yes |
safety Integrated Level | | |
| | SIL3 |
SIL claim limit (for a subsystem) / according to EN 62061 | | 3 |
Performance Level (PL) | | |
| | e |
Category / according to EN 954-1 | | 4 |
Category / according to ISO 13849-1 | | 4 |
Hardware fault tolerance / according to IEC 61508 | | 1 |
Safety device type / according to IEC 61508-2 | | Type A |
Probability of dangerous failure per hour (PFHD) / with high demand rate / according to EN 62061 | 1/h | 0.15E-8 |
Average probability of failure on demand (PFDavg) / with low demand rate / according to IEC 61508 | 1/h | 0.13E-5 |
T1 value / for proof test interval or service life / according to IEC 61508 | a | 20 |
Number of outputs / as contact-affected switching element | | |
- as NC contact / for reporting function / instantaneous switching
| | 2 |
- as NO contact / safety-related / instantaneous switching
| | 3 |
- as NO contact / safety-related/ delayed switching
| | 0 |
Number of outputs / as contact-less semiconductor switching element | | |
| | |
| | 0 |
| | 0 |
| | |
| | 0 |
| | 0 |
Stop category / according to DIN EN 60204-1 | | 0 |
|
General technical details: | | |
Design of the input | | |
- cascading-entrance/operation-even switching
| | No |
| | Yes |
| | Yes |
Design of the electrical connection / jumper socket | | Yes |
Operating cycles / maximum | 1/h | 1,000 |
Switching capacity current | | |
- of NO contacts of relay outputs
| | |
| | |
| A | 6 |
| A | 0.2 |
| A | 0.1 |
| | |
| A | 6 |
| A | 6 |
- of NC contacts of relay outputs
| | |
| | |
| A | 6 |
| A | 0.2 |
| A | 0.1 |
| | |
| A | 6 |
| A | 6 |
Thermal current / of the contact-affected switching element / maximum | A | 6 |
Electrical operating cycles as operating time / typical | | 100,000 |
Mechanical operating cycles as operating time / typical | | 10,000,000 |
Design of the fuse link / for short-circuit protection of the NO contacts of the relay outputs / required | | gL/gG: 6 A, or quick: 10 A |
Resistance to direct current / of the cable / maximum | ? | 30 |
Cable length / between sensor and electronic evaluation device / with Cu 1.5 mm? and 150 nF/km / maximum | m | 1,000 |
Make time / with automatic start | | |
| ms | 150 |
Make time / with monitored start | | |
|