| SIRIUS SOFT STARTER, S0, 12.5A, 5.5KW/400V, 40 DEGR., AC 200-480V, AC/DC 24V, SPRING-LOADED TERMINALS |
|
General details: |
product brand name | | SIRIUS |
Product equipment | | |
- integrated bridging contact system
| | Yes |
| | Yes |
Product function | | |
- intrinsic device protection
| | Yes |
- motor overload protection
| | Yes |
- evaluation of thermal resistor motor protection
| | No |
| | Yes |
- adjustable current limitation
| | Yes |
| | No |
Product component / outlet for enine brake | | No |
Item designation | | |
- according to DIN EN 61346-2
| | Q |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | G |
|
Power Electronics: |
product designation | | soft starters for standard applications |
Operating current | | |
| A | 12.5 |
| A | 11 |
| A | 10 |
Emitted mechanical power / for three-phase servomotors | | |
- at 230 V / at standard switching / at 40 °C
| | |
| W | 3,000 |
- at 400 V / at standard switching / at 40 °C
| | |
| W | 5,500 |
yielded mechanical performance (hp) / for three-phase squirrel cage motors / at 200/208 V / at standard circuit / at 50 °C / rated v
alue | hp | 3 |
Operating frequency | | |
| Hz | 50… 60 |
Relative negative tolerance / of the operating frequency | % | -10 |
Relative positive tolerance / of the operating frequency | % | 10 |
Operating voltage / with standard circuit / rated value | V | 200… 480 |
Relative negative tolerance / of the operating voltage / with standard circuit | % | -15 |
Relative positive tolerance / of the operating voltage / with standard circuit | % | 10 |
Minimum load in % of l_M | % | 20 |
Adjustable rated current / of the motor / for motor overload protection / minimum | A | 5 |
Continuous operating current in % of l_e / at 40°C | % | 115 |
Active power loss / at operating current / at 40°C / during operating phase / typical | W | 2 |
|
Control electronics: |
Type of voltage / of the controlled supply voltage | | AC/DC |
Control supply voltage frequency / 1 / rated value | Hz | 50 |
Control supply voltage frequency / 2 / rated value | Hz | 60 |
Relative negative tolerance / of the control supply voltage frequency | % | -10 |
Relative positive tolerance / of the control supply voltage frequency | % | 10 |
Control supply voltage / 1 | | |
| V | 24 |
| V | 24 |
Relative negative tolerance / of the control supply voltage / at 60 Hz / for AC | % | -20 |
Relative positive tolerance / of the control supply voltage / at 60 Hz / for AC | % | 20 |
Control supply voltage / 1 / for DC / rated value | V | 24 |
Relative negative tolerance / of the control supply voltage / for DC | % | -20 |
Relative positive tolerance / of the control supply voltage / for DC | % | 20 |
Type of display / for fault signal | | red |
|
Mechanical design: |
Size of the engine control device | | S0 |
Width | mm | 45 |
Height | mm | 150 |
Depth | mm | 155 |
Type of mounting | | screw and snap-on mounting |
Built in orientation | | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
Distance, to be maintained, to the ranks assembly | | |
| mm | 60 |
| mm | 15 |
| mm | 40 |
Altitude of installation site / at a height over sea level | m | 5,000 |
Cable length / maximum | m | 300 |
Number of poles / for main current circuit | | 3 |
|
Electrical connections: |
Design of the electrical connection | | |
| | spring-loaded terminals |
- for auxiliary and control current circuit
| | spring-loaded terminals |
Number of NC contacts / for auxiliary contacts | | 0 |
Number of NO contacts / for auxiliary contacts | | 2 |
Number of change-over switches / for auxiliary contacts | | 1 |
Type of the connectable conductor cross-section / for main contacts / for box terminal / when using the front clamping point | | |
| | 2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² |
- finely stranded / with conductor end processing
| | 2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²) |
Type of the connectable conductor cross-section / for AWG conductors / for main contacts / for box terminal | | |
- when using the front c
lamping point