21BD248ACANNAEC0NNNN-HD-B0-C1-J2-J4-L1-L2-N2-P3-S13 - PF700 AC Configured Drive, 480 VAC, 3 PH, 6 Pulse (D), 248 Amps Normal Duty, 180 Amps Heavy Duty (248), 150 HP Heavy Duty, NEMA 1 / IP20, No Bypass (-B0), Drive Circuit Breaker (-P3), , Line Reactor, Mtd & Wired, 3%, Input (-L1)Line Reactor, Mtd & Wired, 3%, Output (-L2), Drive Only Control Power (-C1), 800F Control Power On P.L. (-S13), , Drive Fault Aux. Contact (-J2)Drive Run Aux. Contact (-J4), Isolated Analog Input - 4-20mA (-N2), - Quad Industry GmbH

Артикул: 21BD248ACANNAEC0NNNN-HD-B0-C1-J2-J4-L1-L2-N2-P3-S13
Наименование: PF700 AC Configured Drive, 480 VAC, 3 PH, 6 Pulse (D), 248 Amps Normal Duty, 180 Amps Heavy Duty (248), 150 HP Heavy Duty, NEMA 1 / IP20, No Bypass (-B0), Drive Circuit Breaker (-P3), , Line Reactor, Mtd & Wired, 3%, Input (-L1)Line Reactor, Mtd & Wired, 3%, Output (-L2), Drive Only Control Power (-C1), 800F Control Power On P.L. (-S13), , Drive Fault Aux. Contact (-J2)Drive Run Aux. Contact (-J4), Isolated Analog Input - 4-20mA (-N2),
Производитель: Allen-Bradley




BASE DRIVE INFORMATION
Input Voltage
480 VAC, 3 PH, 6 Pulse (D)
Drive Duty Cycle
Heavy Duty Cycle (-HD)
Current Rating
248 Amps Normal Duty, 180 Amps Heavy Duty (248)
Frame Size
Frame Size 6
Enclosure
IP20 / NEMA Type 1 (A)
NOTES
Note(s):
Information and Data is subject to change.
Please confirm information with factory at time of order entry.
(Drive Photo may NOT show selected Human Interface Module.)
INSTALLED OPTIONS
Human Interface Module
Door Mounted LCD Display, Full Numeric Keypad, IP20, Nema 1. (C)
Drive Unit Documentation
English User Manual (A)
Brake IGBT
No Brake IGBT (N)
Brake Resistor
Without Drive Mounted Brake Resistor (N)
Filter Options
Filter with CM Core (A)
Internal Communication Module
ETHERNET (E)
Drive Unit I/O Options
Vector Control with 24V I/O
Feedback Option
No FDBK PCB (0)
SYSTEM OPTIONS
Bypass Options
No Bypass (-B0)
Input Power Devices
Drive Circuit Breaker (-P3)
Power Filtering
Line Reactor, Mtd & Wired, 3%, Input (-L1)
Line Reactor, Mtd & Wired, 3%, Output (-L2)
Control Power
Drive Only Control Power (-C1)
Operator Devices
800F Control Power On P.L. (-S13)
Control Interface
Drive Fault Aux. Contact (-J2)
Drive Run Aux. Contact (-J4)
System Feedback
Isolated Analog Input - 4-20mA (-N2)






Configured Drive Storage Instructions
Dimension Drawing (DWG)
Dimension Drawing (PDF)


21BD248ACANNAEC0NNNNHDB0C1J2J4L1L2N2P3S13