21BD5P0HJAYYAPD0NNNN-HD-B1-C5-L1-L2-P4-P11-S1-S14 - PF700 AC Configured Drive, 480 VAC, 3 PH, 6 Pulse (D), 5 Amps (5P0), 2 HP Heavy Duty, NEMA 12 / IP54, Manual Bypass using 800F line (-B1), Drive/Bypass Mode Circuit Breaker (-P4)Drive Input Contactor (-P11), , Line Reactor, Mtd & Wired, 3%, Input (-L1)Line Reactor, Mtd & Wired, 3%, Output (-L2), User Supplied 120VAC Control Power (-C5), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1)800F Drive Mode P.L. & Bypass Mode P.L. (-S14), , , , - Quad Industry GmbH

Артикул: 21BD5P0HJAYYAPD0NNNN-HD-B1-C5-L1-L2-P4-P11-S1-S14
Наименование: PF700 AC Configured Drive, 480 VAC, 3 PH, 6 Pulse (D), 5 Amps (5P0), 2 HP Heavy Duty, NEMA 12 / IP54, Manual Bypass using 800F line (-B1), Drive/Bypass Mode Circuit Breaker (-P4)Drive Input Contactor (-P11), , Line Reactor, Mtd & Wired, 3%, Input (-L1)Line Reactor, Mtd & Wired, 3%, Output (-L2), User Supplied 120VAC Control Power (-C5), 800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1)800F Drive Mode P.L. & Bypass Mode P.L. (-S14), , , ,
Производитель: Allen-Bradley




BASE DRIVE INFORMATION
Input Voltage
480 VAC, 3 PH, 6 Pulse (D)
Drive Duty Cycle
Heavy Duty Cycle (-HD)
Current Rating
5 Amps (5P0)
Frame Size
Frame Size 0
Enclosure
IP54 / NEMA 12, Fan & Filters (H)
NOTES
Note(s):
Information and Data is subject to change.
Please confirm information with factory at time of order entry.
(Drive Photo may NOT show selected Human Interface Module.)
INSTALLED OPTIONS
Human Interface Module
Door Mounted Full Numeric LCD HIM, NEMA UL Type 1/12. (J)
Drive Unit Documentation
English User Manual (A)
Brake IGBT
Brake IGBT Installed (Y)
Brake Resistor
Drive Mounted Brake Resistor Installed (Y)
Filter Options
Filter with CM Core (A)
Internal Communication Module
Profibus DP (P)
Drive Unit I/O Options
Vector Control with 120V I/O
Feedback Option
No FDBK PCB (0)
SYSTEM OPTIONS
Bypass Options
Manual Bypass using 800F line (-B1)
Input Power Devices
Drive/Bypass Mode Circuit Breaker (-P4)
Drive Input Contactor (-P11)
Power Filtering
Line Reactor, Mtd & Wired, 3%, Input (-L1)
Line Reactor, Mtd & Wired, 3%, Output (-L2)
Control Power
User Supplied 120VAC Control Power (-C5)
Operator Devices
800F Hand/Off/Auto S.S. (Start/Stop/Speed Ref) (-S1)
800F Drive Mode P.L. & Bypass Mode P.L. (-S14)






Configured Drive Storage Instructions
Dimension Drawing (DWG)
Dimension Drawing (PDF)


21BD5P0HJAYYAPD0NNNNHDB1C5L1L2P4P11S1S14
21BD5-P0HJA-YYAPD0NNNNHDB1C5L1L2P4P11S1S14
21B-D5P0HJAYYAPD0NNNNHDB1C5L1L2P4P11S1S14
21BD5 P0HJA YYAPD0NNNNHDB1C5L1L2P4P11S1S14
21B D5P0HJAYYAPD0NNNNHDB1C5L1L2P4P11S1S14