1SBT1
Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
1SBT132500R0001
|
EL25P1 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.)
|
ABB
|
1SBT152000R0002
|
ES2000S (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
1SBT152000R0001
|
ES2000F (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
1SBT152000R9725
|
ES2000-9725 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
1SBT160050R0001
|
VS50B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT160500R0001
|
VS500B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT161000R0001
|
VS1000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT161500R0001
|
VS1500B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT160125R0001
|
VS125B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT160250R0001
|
VS250B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 4 M5 studs and 3 Faston 6.35 x 0.8 Options: - Primary connection: 2 separated High Voltage cables. - Secondary connection: Shielded cable (2 m), M5 inserts, Lemo connector. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT162000R0001
|
VS2000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT164200R0001
|
VS4200B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT164000R0001
|
VS4000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT163000R0001
|
VS3000B (Sensor for AC, DC or pulsating voltage measurement. The VS range is based on electronic technology with electrical insulation between the primary and secondary circuits. Coated electronic circuit. Plastic case and insulating resin are self-extinguishing. Direction of the current: A positive primary differential voltage (UHT+ - UHT- > 0) results in a positive secondary output current from terminal M. Protections: - of the measuring circuit against short-circuits. - of the measuring circuit against opening. - of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Tightening torque for M5 terminal studs (N.m): 2 N.m. Primary connection: 2 M5 studs Standard secondary connections: 3 M5 studs Options - Primary connection: 2 separated High Voltage cables. - Secondary connection: shielded cable (2 m), M5 inserts, Lemo connector. - Nominal secondary current ISN : ISN (for UPN)= 20 mA or ISN (for UPN) = 80 mA. For other options please contact us. Suitable for Industrial and Railway applications.)
|
ABB
|