1SBT1
Àðòèêóë |
Íàèìåíîâàíèå |
Ïðîèçâîäèòåëü |
1SBT172000R9945
|
CS2000-9945 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT172000R9944
|
CS2000-9944 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT172000R0004
|
CS2000BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT172000R0003
|
CS2000BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R9943
|
CS1000-9943 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R9942
|
CS1000-9942 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R9941
|
CS1000-9941 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R9940
|
CS1000-9940 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R0004
|
CS1000BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R0003
|
CS1000BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R0002
|
CS1000BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT171000R0001
|
CS1000BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170503R0004
|
CS503BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170503R0003
|
CS503BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170503R0002
|
CS503BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170503R0001
|
CS503BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170500R9913
|
CS500-9913 (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170500R0004
|
CS500BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170500R0003
|
CS500BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170500R0002
|
CS500BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170500R0001
|
CS500BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170300R0004
|
CS300BRVE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170300R0003
|
CS300BRE (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170300R0002
|
CS300BRV (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT170300R0001
|
CS300BR (Sensor for AC, DC or pulsating current measurement. The CS range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for horizontal or vertical mounting, with side plates. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Internal electrostatic screen: All CS sensors have an electrostatic screen, this is connected to the screen terminal "E". Depending on the version, when this screen terminal "E" is not provided, the screen is connected to the (–) terminal of the sensor. Protections: -of the measuring circuit against short-circuits. -of the measuring circuit against opening. -of the power supply against polarity reversal. Burn-in test in accordance with FPTC 404304 cycle. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Standard secondary connections: M5 studs and Faston 6.35 x 0.8: see page 80 for details. Suitable for Industrial and Railway applications.)
|
ABB
|
1SBT130100R0002
|
EL100P2BB (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Primary bar included. Secondary connection: 3 soldering pins. Suitable for PCB mounting.)
|
ABB
|
1SBT130100R0001
|
EL100P2 (Sensor for AC, DC or pulsating current measurement. The EL range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor (the temperature of the primary conductor in contact with the case must not exceed 100 °C) Secondary connection: 3 soldering pins. Suitable for PCB mounting.)
|
ABB
|
1SBT191000R9888
|
ESM1000-9888 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
1SBT191000R9887
|
ESM1000-9887 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
1SBT191000R9886
|
ESM1000-9886 (Sensor for AC, DC or pulsating current measurement. The ES range is based on Closed Loop Hall Effect technology with galvanic insulation between the primary and secondary circuits. Plastic case and insulating resin are self-extinguishing. Fixing holes in the case moulding for two positions at right angles. Direction of the current: A primary current flowing in the direction of the arrow results in a positive secondary output current from terminal M. Primary connection: Hole for primary conductor. The temperature of the primary conductor in contact with the case must not exceed 100 °C. Secondary connection: Molex type HE14 connector, JST connector (ref.: B3P-VH), or 3 x 200 mm cables (cross section 0.38 mm²) Suitable for Industrial applications.)
|
ABB
|
Òîâàðû
1 - 30 èç 74
Íà÷àëî | Ïðåä. |
1
2
3
|
Ñëåä. |
Êîíåö
| Âñå
|