art.GJL1313061R6108 - TBC7-30-10-68 Mini Contactor 140-260VDC (The TBC7-30-10 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contact | Quad Industry GmbH
Àðòèêóë: GJL1313061R6108
Íàèìåíîâàíèå: TBC7-30-10-68 Mini Contactor 140-260VDC (The TBC7-30-10 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.)
Ïðîèçâîäèòåëü: ABB
TBC7-30-10-68
General Information
Extended Product Type:
TBC7-30-10-68
Product ID:
GJL1313061R6108
EAN:
4013614313691
Catalog Description:
TBC7-30-10-68 Mini Contactor 140-260VDC
Long Description:
The TBC7-30-10 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or switching of control signals. Further features are the noiseless and hum-free coil, a switch position indication and the integrated possibility for rail or wall mounting.
at 40 ??C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Number of Auxiliary Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Rated Operational Current AC-15 (Ie):
(120 V) 4 A (220 / 240 V) 4 A (24 V) 4 A (380 / 400 V) 3 A (500 V) 2 A
Rated Operational Current DC-13 (Ie):
(110 V) 0.7 A (220 / 240 V) 0.4 A (24 V) 2.5 A
Conventional Free-air Thermal Current (Ith):
Main Circuit 20 A
Rated Control Circuit Voltage (Uc):
200 V DC
Coil Operating Limits:
(acc. to IEC 60947-4-1) for DC supply Uc Min. ... Uc Max. (at >> òÉä 55 ??C)
Degree of Protection:
Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability:
10000000 cycle
Minimum Switching Capacity:
17 V 5 mA
Maximum Electrical Switching Frequency:
AC-1 300 cycles per hour AC-15 600 cycles per hour AC-3 600 cycles per hour DC-1 600 cycles per hour DC-13 600 cycles per hour DC-3 600 cycles per hour
Auxiliary Circuit 0.8 ... 1.1 N??m Control Circuit 0.8 ... 1.1 N??m Main Circuit 0.8 ... 1.1 N??m
Mounting on DIN Rail:
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Power Loss:
at Rated Operating Conditions per Pole 2 W
Standards:
IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1
Remarks:
No CA6 or CAF6 mountable
Environmental
Ambient Air Temperature:
Operation -30 ... +70 ??C Storage -40 ... +85 ??C
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 15g
Resistance to Vibrations acc. to IEC 60068-2-6:
5g / 5 ... 150 Hz
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Full Load Amps Motor Use:
(240 V AC) Single Phase 10 A (440 ... 480 V AC) Three Phase 7.6 A
Horsepower Rating UL/CSA: