art.GJH1213001R5221 - KC6-22Z-2.4-51 Mini Contactor Relay 17-32VDC, 2.4W (The KC6-22Z mini contactor relay is a compact 4 pole contactor relay with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors | Quad Industry GmbH
Àðòèêóë: GJH1213001R5221
Íàèìåíîâàíèå: KC6-22Z-2.4-51 Mini Contactor Relay 17-32VDC, 2.4W (The KC6-22Z mini contactor relay is a compact 4 pole contactor relay with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors relays are used in residential buldings, commercial buildings and industrial applications for switching of control signals up to 3 A / 400 V (AC-15). Due to the low coil consumption, this device can be directly controlled by a PLC. Further features are the noiseless and hum-free coil and a a switch position indication.)
Ïðîèçâîäèòåëü: ABB
KC6-22Z-2.4-51
General Information
Extended Product Type:
KC6-22Z-2.4-51
Product ID:
GJH1213001R5221
EAN:
4013614194351
Catalog Description:
KC6-22Z-2.4-51 Mini Contactor Relay 17-32VDC, 2.4W
Long Description:
The KC6-22Z mini contactor relay is a compact 4 pole contactor relay with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors relays are used in residential buldings, commercial buildings and industrial applications for switching of control signals up to 3 A / 400 V (AC-15). Due to the low coil consumption, this device can be directly controlled by a PLC. Further features are the noiseless and hum-free coil and a a switch position indication.
Auxiliary Circuit 12 ... 240 V DC Auxiliary Circuit 12 ... 500 V AC/DC Auxiliary Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp):
Auxiliary Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V acc. to UL/CSA 600 V
Number of Main Contacts NC:
0
Number of Main Contacts NO:
0
Number of Auxiliary Contacts NC:
2
Number of Auxiliary Contacts NO:
2
Rated Operational Current AC-15 (Ie):
(120 V) 4 A (220 / 240 V) 4 A (240 V) 4 A (24 V) 4 A (380 / 400 V) 3 A (500 V) 2 A
Rated Operational Current DC-13 (Ie):
(110 V) 0.7 A (220 / 240 V) 0.4 A (24 V) 2.5 A
Conventional Free-air Thermal Current (Ith):
Auxiliary Circuit 6 A
Rated Control Circuit Voltage (Uc):
17 ... 32 V DC
Coil Operating Limits:
(acc. to IEC 60947-4-1) for DC supply Uc Min. ... Uc Max. (at >> òÉä 55 ??C) (acc. to IEC 60947-5-1) for DC supply 0.85 ... 1.1 x Uc (at >> òÉä 55 ??C)
Degree of Protection:
Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability:
10000000 cycle
Minimum Switching Capacity:
17 V 5 mA
Maximum Electrical Switching Frequency:
AC-15 600 cycles per hour DC-13 600 cycles per hour