Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 947-4-1. Electromagnetic compatibility (EMC) acording to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Supply Circuit 50 Hz Supply Circuit 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-5-1, q = 40 ??C 10 A
Rated Operational Current AC-15 (Ie):
(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
Short-Circuit Protective Devices:
gG Type Fuses 10 A
Rated Short-time Withstand Current (Icw):
for 0.1 s 100 A for 1 s 50 A
Rated Operational Current DC-13 (Ie):
(125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Mechanical Switching Frequency:
6000 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at >> тЙд 55 ??C) ??C
Rated Control Circuit Voltage (Uc):
DC Operation 110 V
Coil Consumption:
Average Holding Value, from Warm State 7 W Average Pull-in Value, from Cold State 7 W
Operate Time:
Between Coil Energization and NO Contact Closing 50 ... 75 ms Between Coil De-energization and NO Contact Opening 15 ... 30 ms Between Coil De-energization and NC Contact Closing 17 ... 32 ms Between Coil Energization and NC Contact Opening 45 ... 70 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied):
2 x M 4
Connecting Capacity Auxiliary Circuit:
Rigid Cable 1 ... 4 mm?? Flexible with Cable End 0.75 ... 2.5 mm??
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP10
Environmental
Ambient Air Temperature:
Near Contactor for Operation in Free Air (Uc) +55 ... +70 ??C Storage -60 тАж +80 ??C Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 ??C Storage -60 тАж +80 ??C Close to Contactor for Storage -60 ... +80 ??C Storage -60 тАж +80 ??C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: A 20 m/s?? Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: B2 15 m/s?? Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: C1 20 m/s?? Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: B1 5 m/s?? Half-sine Pulse for 11 ms, No Change in Contact Position, Shock Direction: C2 20 m/s??