art.1SAX811001R1101 - E800DU-800 Electronic Overload Relay (The E800DU-800 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use li | Quad Industry GmbH

Àðòèêóë: 1SAX811001R1101
Íàèìåíîâàíèå: E800DU-800 Electronic Overload Relay (The E800DU-800 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected with a mounting kit to the contactors.)
Ïðîèçâîäèòåëü: ABB


E800DU-800

General Information

  • Extended Product Type:
    E800DU-800
  • Product ID:
    1SAX811001R1101
  • EAN:
    4013614395444
  • Catalog Description:
    E800DU-800 Electronic Overload Relay
  • Long Description:
    The E800DU-800 is an self-supplied electronic overload relay, which means no extra external supply is needed. It offers reliable and fast protection for motors in the event of overload or phase failure. Easy to use like a thermal overload relay and compatible with standard motor applications, the electronic overload relay is convincing, above all, due to its wide setting range, high accuracy, high operational temperature range and the possibility to select a trip class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected with a mounting kit to the contactors.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900
  • Replacement Product ID (NEW):
    1SAX821001R1101

Dimensions

  • Product Net Width:
    245 mm
  • Product Net Height:
    120 mm
  • Product Net Depth:
    185.6 mm
  • Product Net Weight:
    3.905 kg

Popular Downloads

Technical

  • Setting Range:
    250 ... 800 A
  • Rated Operational Voltage:
    Auxiliary Circuit 600 V AC/DC
    Main Circuit 1000 V AC
  • Rated Operational Current (Ie):
    800 A
  • Rated Operational Current AC-3 (Ie):
    800 A
  • Rated Frequency (f):
    Auxiliary Circuit 50 Hz
    Auxiliary Circuit 60 Hz
    Auxiliary Circuit DC
    Main Circuit 50 Hz
    Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):
    Auxiliary Circuit 6 kV
    Main Circuit 8 kV
  • Rated Insulation Voltage (Ui):
    1000 V
  • Number of Poles:
    3
  • Number of Auxiliary Contacts NC:
    1
  • Number of Auxiliary Contacts NO:
    1
  • Number of Protected Poles:
    3
  • Conventional Free-air Thermal Current (Ith):
    Auxiliary Circuit NC 6 A
    Auxiliary Circuit NO 6 A
  • Rated Operational Current AC-15 (Ie):
    (240 V) NC 3 A
    (240 V) NO 3 A
    (400 V) NC 1.1 A
    (400 V) NO 1.1 A
    (500 V) NC 0.7 A
    (500 V) NO 0.7 A
  • Rated Operational Current DC-13 (Ie):
    (125 V) NC 0.55 A
    (125 V) NO 0.4 A
    (24 V) NC 1.5 A
    (24 V) NO 1.5 A
    (250 V) NC 0.27 A
    (250 V) NO 0.2 A
    (60 V) NC 0.55 A
    (60 V) NO 0.5 A
  • Degree of Protection:
    Housing IP20
    Main Circuit Terminals IP00
  • Pollution Degree:
    3
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible 1/2x 0.75 ... 2.5 mm²
    Rigid 1/2x 1 ... 4 mm²
  • Tightening Torque:
    Auxiliary Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:
    Auxiliary Circuit 9 mm
  • Recommended Screw Driver:
    Auxiliary Circuit Pozidriv 2
  • Mounting Position:
    Position 1 to 6
  • Suitable For:
    AF580
    AF750
  • Standards:
    IEC/EN 60947-1
    IEC/EN 60947-4-1
    IEC/EN 60947-5-1
    UL 60947-1
    UL 60947-4-1

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +70 °C
    Operation Compensated -25 ... +70 °C
    Storage -25 ... +70 °C
  • Ambient Air Temperature Compensation:
    Yes
  • Maximum Operating Altitude Permissible:
    2000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V AC
  • Ampere Rating UL/CSA:
    800 A
  • Connecting Capacity Auxiliary Circuit UL/CSA:
    Flexible 1/2x 16-10 AWG
    Stranded 1/2x 16-10 AWG
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 7 in·lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    274 mm
  • Package Level 1 Height:
    147 mm
  • Package Level 1 Length:
    256 mm
  • Package Level 1 Gross Weight:
    4.225 kg

Classifications

  • Object Classification Code:
    F
  • E-nummer:
    3228791
  • ETIM 4:
    EC001080 - Electronic overload relay
  • ETIM 5:
    EC001080 - Electronic overload relay
  • ETIM 6:
    EC001080 - Electronic overload relay
  • eClass:
    7.0 27371502
  • UNSPSC:
    39121521

Where Used (as part of "kit")

Identifier Description Type
3BHB026772R0001
3BHB026772R0001 Kit Kit
3BHB026772R0002
3BHB026772R0002 Kit Kit
3BHB026772R0003
3BHB026772R0003 Kit Kit
3BHB026772R0004
3BHB026772R0004 Kit Kit
3BHB026772R0005
3BHB026772R0005 Kit Kit
3BHB026772R0011
3BHB026772R0011 Kit Kit




Image 0 alt text

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Electronic Overload Relays


Íàçàä â ðàçäåë