Àðòèêóë: 1SFL497001R7200
Íàèìåíîâàíèå: CONTACTOR#AF185-30-00#20-60V DC | 1SFL497001R7200 | AF185-30-00 20-60V DC
Ïðîèçâîäèòåëü: ABB
|
|
General Information Extended Product Type: AF185-30-00 20-60V DC Product ID: 1SFL497001R7200 Catalog Description: CONTACTOR#AF185-30-00#20-60V DC Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC Additional Information Catalog Description: CONTACTOR#AF185-30-00#20-60V DC Coil Consumption: Holding at Max Rated Control Circuit Voltage DC 3 W Pull-in at Max Rated Control Circuit Voltage DC 350 W Coil Operating Limits: (acc. to IEC 60947-4-1) Uc (at ?? òÉä 70 ??C) ??C Connecting terminals (delivered in open position) Coils terminals: M 3.5 (+,-) pozidriv 2 screw with cable clamp Connecting terminals (delivered in open position) Main poles: Flat type c/w screws and bolts Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q=40??C 275 A Data Sheet, Technical Information: Declaration of Conformity - CE: Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 Drop-out Voltage in % of Uc: Environmental Information: IIT Publishing Status: Level 0 - Information enabled Instructions and Manuals: Invoice Description: CONTACTOR#AF185-30-00#20-60V DC Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 20-60 V, DC Maximum Electrical Switching Frequency: AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 300 cycles per hour Maximum Mechanical Switching Frequency: Maximum Operating Altitude Permissible: Maximum ?Îpeak Permissible: Number of Main Contacts NO: Object Classification Code: Operate Time: Between Coil Energization and N.O. Contact Closing 50 òÀæ 90 ms Between Coil De-energization and N.C. Contact Closing 40 òÀæ 50 ms Package Level 1 Gross Weight: Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: Rated Control Circuit Voltage (Uc): Rated Impulse Withstand Voltage (Uimp): Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Making Capacity AC-3 acc. to IEC 60947-4-1: Rated Operational Current AC-1 (Ie): (690V) 40??C 275 A (690V) 55??C 250 A (690V) 70??C 180 A Rated Operational Current AC-3 (Ie): (220/230/240V) 55??C 185 A (380V/400V) 55??C 185 A (415V) 55??C 185 A (440V) 55??C 185 A (500V) 55??C 170 A (690V) 55??C 170 A Rated Operational Power AC-3 (Pe): (220 / 230 / 240V) 55 kW (380 / 400V) 90 kW (415V) 90 kW (440V) 90 kW (500V) 110 kW (690V) 132 kW Rated Operational Power AC-6a (Pe): (220 / 240V) 45 kV??A (380 / 400V) 75 kV??A (415 / 440V) 80 kV??A (500V) 100 kV??A (660 / 690V) 130 kV??A Rated Operational Voltage (Ue): RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment Short Description: CONTACTOR#AF185-30-00#20-60V DC Short-Circuit Protective Devices:
|