art.1SBH143061R6640 - TNL40E 90-150V DC Contactor Relay (TNL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magn | Quad Industry GmbH

Артикул: 1SBH143061R6640
Наименование: TNL40E 90-150V DC Contactor Relay (TNL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available TNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.)
Производитель: ABB


TNL40E 90-150V DC

General Information

  • Extended Product Type:
    TNL40E 90-150V DC
  • Product ID:
    1SBH143061R6640
  • EAN:
    3471522329660
  • Catalog Description:
    TNL40E 90-150V DC Contactor Relay
  • Long Description:
    TNL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available TNL... contactor relays are fitted with low consumption DC coils and offer a large coil voltage range.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    44 mm
  • Product Net Depth:
    97 mm
  • Product Net Height:
    78 mm
  • Product Net Weight:
    0.520 kg

Technical

  • Number of Auxiliary Contacts NO:
    4
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 Hz
    Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-5-1, q = 40 ??C 16 A
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (380 / 440 V) 3 A
    (500 V) 2 A
    (690 V) 2 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit - gG Type Fuses 10 A
  • Rated Short-time Withstand Current (Icw):
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Electrical Switching Frequency:
    1200 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (125 V) 0.55 / 69 A
    (24 V) 6 / 144 A
    (250 V) 0.3 / 75 A
    (48 V) 2.8 / 134 A
    (72 V) 1 / 72 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    > 20 million
  • Maximum Mechanical Switching Frequency:
    6000 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    DC Operation 90 тАж 150 V
  • Coil Consumption:
    Holding DC (Umin / Umax) 2.5 / 8.5 W
    Pull-in DC (Umin / Umax) 2.5 / 8.5 W
  • Operate Time:
    Between Coil Energization and NO Contact Closing 50 ... 100 ms
    Between Coil De-energization and NO Contact Opening 10 ... 17 ms
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm??
    Rigid Cable 1 ... 4 mm??
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Near Contactor for Operation in Free Air -40 ... +55 ??C
    Close to Contactor for Storage -60 ... +80 ??C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 20 g
    Open, Shock Direction: A 10 g
    Closed, Shock Direction: B1 15 g
    Open, Shock Direction: B1 5 g
    Shock Direction: B2 10 g
    Closed, Shock Direction: C1 20 g
    Open, Shock Direction: C1 8 g
    Closed, Shock Direction: C2 14 g
    Open, Shock Direction: C2 8 g
  • RoHS Status:
    Following EU Directive 2011/65/EC

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    86 mm
  • Package Level 1 Length:
    141 mm
  • Package Level 1 Height:
    51 mm
  • Package Level 1 Gross Weight:
    0.52 kg
  • Package Level 1 EAN:
    3471522329660
  • Package Level 2 Units:
    28 piece
  • Package Level 3 Units:
    336 piece

Classifications

  • Object Classification Code:
    K
  • ETIM 4:
    EC000196 - Contactor relay
  • ETIM 5:
    EC000196 - Contactor relay
  • ETIM 6:
    EC000196 - Contactor relay
  • UNSPSC:
    39121500




Image 0 alt text

Categories

  • Products >> Low Voltage Products and Systems >> Control Products >> Contactors >> Block Contactors


Назад в раздел