art.1SAZ911201R1006 - TF96-96 Thermal Overload Relay (The TF96-96 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip cl | Quad Industry GmbH

Àðòèêóë: 1SAZ911201R1006
Íàèìåíîâàíèå: TF96-96 Thermal Overload Relay (The TF96-96 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.)
Ïðîèçâîäèòåëü: ABB


TF96-96

General Information

  • Extended Product Type:
    TF96-96
  • Product ID:
    1SAZ911201R1006
  • EAN:
    4013614483035
  • Catalog Description:
    TF96-96 Thermal Overload Relay
  • Long Description:
    The TF96-96 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    69.9 mm
  • Product Net Height:
    106.9 mm
  • Product Net Depth:
    106.3 mm
  • Product Net Weight:
    0.53 kg

Popular Downloads

Technical

  • Setting Range:
    84 ... 96 A
  • Rated Operational Voltage:
    Auxiliary Circuit 600 V AC/DC
    Main Circuit 690 V AC
    Main Circuit 440 V DC
  • Rated Operational Current (Ie):
    96 A
  • Rated Operational Current AC-3 (Ie):
    96 A
  • Rated Frequency (f):
    Auxiliary Circuit 50 Hz
    Auxiliary Circuit 60 Hz
    Auxiliary Circuit DC
    Main Circuit 50 Hz
    Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):
    Auxiliary Circuit 6 kV
    Main Circuit 8 kV
  • Rated Insulation Voltage (Ui):
    690 V
  • Number of Poles:
    3
  • Number of Auxiliary Contacts NC:
    1
  • Number of Auxiliary Contacts NO:
    1
  • Number of Protected Poles:
    3
  • Conventional Free-air Thermal Current (Ith):
    Auxiliary Circuit NC 6 A
    Auxiliary Circuit NO 4 A
  • Rated Operational Current AC-15 (Ie):
    (120 V) NC 3 A
    (120 V) NO 0.75 A
    (240 V) NC 3 A
    (240 V) NO 0.75 A
    (400 V) NC 0.75 A
    (400 V) NO 0.75 A
    (500 V) NC 0.75 A
    (500 V) NO 0.75 A
  • Rated Operational Current DC-13 (Ie):
    (125 V) NC 0.55 A
    (125 V) NO 0.55 A
    (24 V) NC 1.25 A
    (24 V) NO 1.25 A
    (250 V) NC 0.27 A
    (250 V) NO 0.27 A
    (500 V) NC 0.15 A
    (500 V) NO 0.15 A
    (60 V) NC 0.55 A
    (60 V) NO 0.55 A
  • Degree of Protection:
    Housing IP20
    Main Circuit Terminals IP10
  • Pollution Degree:
    3
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm??
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm??
    Flexible 1/2x 0.75 ... 1 mm??
    Flexible 1/2x 1 ... 2.5 mm??
    Rigid 1/2x 0.75 ... 4 mm??
  • Connecting Capacity Main Circuit:
    Flexible with Ferrule 1/2x 6 ... 35 mm??
    Flexible with Ferrule 1x 6 òÀæ 50 mm??
    Flexible with Insulated Ferrule 1/2x 6 ... 16 mm??
    Flexible with Insulated Ferrule 1x 6 òÀæ 50 mm??
    Flexible 1/2x 6 ... 35 mm??
    Flexible 1x 6 òÀæ 50 mm??
    Rigid 1/2x 6 ... 35 mm??
    Rigid 1x 6 òÀæ 50 mm??
  • Tightening Torque:
    Auxiliary Circuit 1 ... 1.2 N??m
    Main Circuit 6.0 ... 9.0 N??m
  • Wire Stripping Length:
    Auxiliary Circuit 9 mm
    Main Circuit 20 mm
  • Recommended Screw Driver:
    Auxiliary Circuit Pozidriv 2
    Main Circuit Hexagon 4
  • Mounting Position:
    Position 1 to 6
  • Power Loss:
    at Rated Operating Conditions per Pole 2.8 ... 3.7 W
  • Suitable For:
    AF80
    AF96
  • Standards:
    IEC/EN 60947-1
    IEC/EN 60947-4-1
    IEC/EN 60947-5-1
    UL 60947-1
    UL 60947-4-1

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +60 ??C
    Operation Compensated -25 ... +60 ??C
    Storage -50 ... +80 ??C
  • Ambient Air Temperature Compensation:
    Yes
  • Maximum Operating Altitude Permissible:
    2000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    11 ms Pulse 25g
  • Resistance to Vibrations acc. to IEC 60068-2-6:
    5g / 3 ... 150 Hz
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V AC
  • Ampere Rating UL/CSA:
    96 A
  • Contact Rating UL/CSA:
    (NC:) B600
    (NC:) Q600
    (NO:) Q600
    (NO:) D300
  • Connecting Capacity Main Circuit UL/CSA:
    Flexible 1x 8-1 AWG
    Flexible 2x 8-3 AWG
    Stranded 1x 8-1 AWG
    Stranded 2x 8-3 AWG
  • Connecting Capacity Auxiliary Circuit UL/CSA:
    Flexible 1/2x 18-12 AWG
    Stranded 1/2x 18-12 AWG
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 9 ... 11 in??lb
    Main Circuit 53 ... 80 in??lb

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    97 mm
  • Package Level 1 Height:
    121 mm
  • Package Level 1 Length:
    97 mm
  • Package Level 1 Gross Weight:
    0.63 kg
  • Package Level 2 Units:
    12 piece
  • Package Level 2 Width:
    280 mm
  • Package Level 2 Height:
    210 mm
  • Package Level 2 Length:
    395 mm
  • Package Level 2 Gross Weight:
    7.946 kg
  • Package Level 2 EAN:
    4013614485473

Classifications

  • Object Classification Code:
    F
  • E-nummer:
    3210275
  • ETIM 4:
    EC000106 - Thermal overload relay
  • ETIM 5:
    EC000106 - Thermal overload relay
  • ETIM 6:
    EC000106 - Thermal overload relay
  • eClass:
    7.0 27371501
  • UNSPSC:
    39121521




Image 0 alt text

Categories

  • Products >> Low Voltage Products and Systems >> Control Products >> Contactors >> Thermal Overload Relays


Íàçàä â ðàçäåë